Biomechanical Stability of Third-Generation Adjustable Suture Loop Devices Versus Continuous Loop Button Device for Cortical Fixation of ACL Tendon Grafts

Deichsel, Adrian; Leibrandt, Lara, Raschke, Michael J; Klimek, Matthias; Oeckenpöhler, Simon; Herbst, Elmar; Kittl, Christoph, Glasbrenner, Johannes

Research article (journal) | Peer reviewed

Abstract

Background: Concerns regarding the primary stability of early adjustable loop button (ALB) devices for cortical fixation of tendon grafts in anterior cruciate ligament reconstruction (ACLR) have led to the development of new implant designs. Purpose: To evaluate biomechanical stability of recent ALB implants in comparison with a continuous loop button (CLB) device. Study design: Controlled laboratory study. Methods: ACLR was performed in a porcine model (n = 40) using 2-strand porcine flexor tendons with a diameter of 8 mm. Three ALB devices (Infinity Button [ALB1 group]; Tightrope II RT [ALB2 group]; A-TACK [ALB3 group]) and 1 CLB device (FlippTack with polyethylene suture) were used for cortical tendon graft fixation. Cyclic loading (1000 cycles up to 250 N) with complete unloading were applied to the free end of the tendon graft using a uniaxial testing machine, followed by load to failure. Elongation, stiffness, yield load, and ultimate failure load were recorded and compared between the groups using a Kruskal-Wallis test with post hoc Dunn correction. Results: Elongation after 1000 cycles at 250 N was similar between groups (ALB1, 4.5 ± 0.7 mm; ALB2, 4.8 ± 0.8 mm; ALB3, 4.5 ± 0.6 mm; CLB, 4.5 ± 0.8 mm), as was load to failure (ALB1, 838 ± 109 N; ALB2, 930 ± 89 N; ALB3, 809 ± 103 N; CLB, 842 ± 80 N). Stiffness was significantly higher in the ALB1 group compared with the CLB group (262.3 ± 21.6 vs 229.3 ± 15.1 N/mm; P < .05). No significant difference was found between the 4 groups regarding yield load. Constructs failed either by rupture of the loop, breakage of the button, or rupture of the tendon. Conclusion: The tested third-generation ALB devices for cortical fixation in ACLR withstood cyclic loading with complete unloading without significant differences to a CLB device. Clinical relevance: The third-generation ALB devices tested in the present study provided biomechanical stability comparable with that of a CLB device. Furthermore, ultimate failure loads of all tested implants exceeded the loads expected to occur in the postoperative period after ACLR. Keywords: ACL reconstruction; adjustable loop button; continuous loop button; cortical fixation.

Details about the publication

JournalOrthopaedic journal of sports medicine (Orthop J Sports Med)
Volume12(4)
StatusPublished
Release year2024 (03/04/2024)
Language in which the publication is writtenEnglish
DOI10.1177/23259671241240375
Link to the full texthttps://journals.sagepub.com/doi/10.1177/23259671241240375
KeywordsACL reconstruction; adjustable loop button; continuous loop button; cortical fixation.

Authors from the University of Münster

Deichsel, Adrian
Clinic for Accident, Hand- and Reconstructive Surgery
Glasbrenner, Johannes
Clinic for Accident, Hand- and Reconstructive Surgery
Herbst, Elmar
Clinic for Accident, Hand- and Reconstructive Surgery
Kittl, Christoph
Clinic for Accident, Hand- and Reconstructive Surgery
Klimek, Matthias
Clinic for Accident, Hand- and Reconstructive Surgery
Oeckenpöhler, Simon Georg
Clinic for Accident, Hand- and Reconstructive Surgery
Raschke, Michael Johannes
Clinic for Accident, Hand- and Reconstructive Surgery