Acromioclavicular and coracoclavicular ligamentous insertion distances depend on the scapular tilt and decrease with anterior direction of the inferior scapula angle

Sußiek, Julia; Wermers, Jens; Raschke, Michael J.; Herbst, Elmar; Dyrna, Felix; Riesenbeck, Oliver; Katthagen, J. Christoph

Research article (journal) | Peer reviewed

Abstract

A variety of reconstruction techniques exist for the operative treatment of a ruptured acromioclavicular and coracoclavicular ligamentous complex. However, the complication rate remains high; between 5 and 89%. The intraoperative distance between the clavicle, acromion and coracoid is important for the refixation quality. In this study, the influence of scapular deflection on coracoclavicular and acromioclavicular distances was analysed.; The ligamentous insertions of 24 fresh-frozen human scapulae were exposed. The coracoclavicular and acromioclavicular ligaments were referenced and captured in a rigid body system using a three-dimensional (3D) measurement arm. The inferior angle of the scapula was manually pulled into maximum anterior and posterior deflection, simulating a patient positioning with or without dorsal scapular support, respectively. Based on the rigid body system, the distances between the ligamentous insertions were calculated. Statistical evaluation was performed by setting the distances in anterior deflection to 100% and considering the other distances relative to this position.; The scapular deflection had a considerable impact on the distance between the ligamentous insertions. Concerning the conoid ligament, the mean distance was almost doubled when the inferior angle pointed posteriorly compared to anterior deflection (195.3 vs 100.0%; p = 0.028). The insertion of the acromioclavicular capsule also showed a significant association with the direction of deflection (posterior = 116.1% vs. anterior = 100%; p = 0.008).; Dorsal support shifting the inferior angle of the scapula anteriorly reduces the distance between the ligamentous insertions. Therefore, a patient position on a shoulder table with posterior support of the scapula is recommended to reliability reduce the acromioclavicular joint. - PURPOSE - METHODS - RESULTS - CONCLUSION

Details about the publication

JournalKnee Surgery, Sports Traumatology, Arthroscopy (Knee Surg Sports Traumatol Arthrosc)
Volume31
Issue2
Page range656-661
StatusPublished
Release year2023
Language in which the publication is writtenEnglish
DOI10.1007/s00167-022-07126-9
KeywordsAcromioclavicular joint injuries; Biomechanics; Shoulder; Coracoclavicular ligaments

Authors from the University of Münster

Dyrna, Felix
Clinic for Accident, Hand- and Reconstructive Surgery
Herbst, Elmar
Clinic for Accident, Hand- and Reconstructive Surgery
Katthagen, Jan Christoph
Clinic for Accident, Hand- and Reconstructive Surgery
Raschke, Michael Johannes
Clinic for Accident, Hand- and Reconstructive Surgery
Riesenbeck, Oliver
Clinic for Accident, Hand- and Reconstructive Surgery
Wermers, Jens
Institute of Musculoskeletal Medicine (IMM)