Prospective study of access site complications of automated contrast injection with peripheral venous access in MDCT.

Wienbeck S, Fischbach R, Kloska SP, Seidensticker P, Osada N, Heindel W, Juergens KU

Research article (journal)

Abstract

The purpose of this article is to prospectively assess the frequency and type of IV injection site complications associated with high-flow power injection of nonionic contrast medium in MDCT.Contrast-enhanced (300-370 mg iodine/mL) MDCT examinations with high flow rates (up to 8 mL/s) using automatic CT injectors were performed according to standardized MDCT protocols. The location, type, and size (16-24 gauge) of IV catheters and volumes, iodine concentration, and flow rates of contrast medium were documented. Patients were questioned about associated discomfort, IV catheter sites were checked, and adverse effects were recorded.Prospectively, 4,457 patients were studied. The injection rate ranged from 1-2.9 mL/s (group 1; n = 1,140) to 3-4.9 mL/s (group 2; n = 2,536) to 5-8 mL/s (group 3; n = 781); 1.2% of the patients experienced extravasations (n = 52). Contrast medium iodine concentration, flow rates, and volumes were not related to the frequency of extravasation. The extravasation rate was highest with 22-gauge IV catheters (2.2%; p < 0.05) independently of the anatomic location. For 20-gauge IV catheters, extravasation rates were significantly higher in the dorsum of the hand than in the antecubital fossa (1.8% vs 0.8%; p = 0.018). Extravasation rates were higher in older patients (>>= 50 vs < 50 years, 0.6% vs 1.4%; p = 0.019). Different iodine concentrations did not trigger significant differences in contrast material reactions (p = 0.782).Automated IV contrast injection applying high flow rates (i.e., up to 8 mL/s) is performed without increased risk of extravasation. The overall extravasation rate was 1.2% and showed no correlation with iodine concentration, flow rates, or contrast material reactions. Performing high flow rates with low-diameter IV catheters (e.g., 22-gauge catheters) and a location of IV catheter in the hand is associated with a higher extravasation rate.

Details about the publication

JournalAmerican Journal of Roentgenology (AJR Am J Roentgenol)
Volume195
Issue4
Page range825-829
StatusPublished
Release year2010
Language in which the publication is writtenEnglish
DOI10.2214/AJR.09.3739
KeywordsContrast Media; Male; Aged; Extravasation of Diagnostic and Therapeutic Materials; Humans; Middle Aged; Adult; Young Adult; Tomography X-Ray Computed; Female; Adolescent; Aged 80 and over; Prospective Studies; Injections Intravenous; Catheterization Peripheral; Contrast Media; Male; Aged; Extravasation of Diagnostic and Therapeutic Materials; Humans; Middle Aged; Adult; Young Adult; Tomography X-Ray Computed; Female; Adolescent; Aged 80 and over; Prospective Studies; Injections Intravenous; Catheterization Peripheral

Authors from the University of Münster

Heindel, Walter Leonhard
Clinic of Radiology
Wienbeck, Susanne
Clinic of Radiology