Impact of Chlorine Dioxide on Pathogenic Waterborne Microorganisms Occurring in Dental Chair Units

Krüger T.I.M.; Herzog S.; Mellmann A.; Kuczius T.

Forschungsartikel (Zeitschrift) | Peer reviewed

Zusammenfassung

Bacterial contamination is a problem in dental unit water lines with the consequence of implementing regular disinfection. In this study, the short-term impact of chlorine dioxide (ClO2) treatment was investigated on the microorganisms Legionella pneumophila and L. anisa, Pseudomonas aeruginosa, Escherichia coli, and Staphylococcus aureus. The environmental background was proven as an important factor regarding the tolerance to 0.4 mg/L ClO2 as saline and phosphate-buffered saline resulted in a higher bacterial reduction than tap water. Gram-positive microorganisms demonstrated higher robustness to ClO2 than Gram-negative, and microorganisms adapted to tap water showed increased stability compared to cultured cells. At high densities, substantial numbers of bacteria were able to withstand disinfection, whereby the use of 4.6 mg/L ClO2 increased the inactivation rate. A massive cell decrease occurred within the first 5 minutes with subsequent plateau formation or slowed cell reduction upon further exposure. This biphasic kinetics cannot be explained by a ClO2 depletion effect alone, because the probability of bacterial subpopulations with increased tolerance should be taken into account, too. Our results prove high disinfection efficiency to microorganisms that were rather found in correlation to the level of bacterial contamination and background solutions than the chosen concentration for ClO2 treatment itself.

Details zur Publikation

FachzeitschriftMicroorganisms
Jahrgang / Bandnr. / Volume11
Ausgabe / Heftnr. / Issue5
Seitenbereich1123null
StatusVeröffentlicht
Veröffentlichungsjahr2023 (26.04.2023)
Sprache, in der die Publikation verfasst istEnglisch
DOI10.3390/microorganisms11051123
Link zum Volltexthttps://api.elsevier.com/content/abstract/scopus_id/85160779824
Stichwörterchlorine dioxide; dental unit waterline; disinfection; infection control; Legionella; Pseudomonas aeruginosa; Staphylococcus aureus; disinfection; infection control

Autor*innen der Universität Münster

Herzog, Susann
Institut für Medizinische Mikrobiologie
Kuczius, Thorsten
Institut für Hygiene
Mellmann, Alexander
Institut für Hygiene