Validation of MALDI-MS imaging data of selected membrane lipids in murine brain with and without laser postionization by quantitative nano-HPLC-MS using laser microdissection

Eiersbrock F, Orthen J, Soltwisch J

Forschungsartikel (Zeitschrift) | Peer reviewed

Zusammenfassung

MALDI mass spectrometry imaging (MALDI-MSI) is a widely used technique to map the spatial distribution of molecules in sectioned tissue. The technique is based on the systematic generation and analysis of ions from small sample volumes, each representing a single pixel of the investigated sample surface. Subsequently, mass spectrometric images for any recorded ion species can be generated by displaying the signal intensity at the coordinate of origin for each of these pixels. Although easily equalized, these recorded signal intensities, however, are not necessarily a good measure for the underlying amount of analyte and care has to be taken in the interpretation of MALDI-MSI data. Physical and chemical properties that define the analyte molecules' adjacencies in the tissue largely influence the local extraction and ionization efficiencies, possibly leading to strong variations in signal intensity response. Here, we inspect the validity of signal intensity distributions recorded from murine cerebellum as a measure for the underlying molar distributions. Based on segmentation derived from MALDI-MSI measurements, laser microdissection (LMD) was used to cut out regions of interest with a homogenous signal intensity. The molar concentration of six exemplary selected membrane lipids from different lipid classes in these tissue regions was determined using quantitative nano-HPLC-ESI-MS. Comparison of molar concentrations and signal intensity revealed strong deviations between underlying concentration and the distribution suggested by MSI data. Determined signal intensity response factors strongly depend on tissue type and lipid species.

Details zur Publikation

FachzeitschriftAnalytical and Bioanalytical Chemistry
Jahrgang / Bandnr. / Volume412
Seitenbereich6875-6886
StatusVeröffentlicht
Veröffentlichungsjahr2020 (25.07.2020)
Sprache, in der die Publikation verfasst istEnglisch
DOI10.1007/s00216-020-02818-y
Link zum Volltexthttps://link.springer.com/article/10.1007%2Fs00216-020-02818-y
StichwörterMALDI; Mass spectrometry imaging; Laser postionization; MALDI-2; Quantification; Signal intensity response; Laser microdissection; Nano-HILIC-nano-ESI-MS; Lipids

Autor*innen der Universität Münster

Orthen, Julian
Institut für Hygiene
Soltwisch, Jens
Institut für Hygiene