Evaluation of biomechanical properties: are porcine flexor tendons and bovine extensor tendons eligible surrogates for human tendons in in vitro studies?

Domnick C., Wieskötter B., Raschke M., Schulze M., Kronenberg D., Wefelmeier M., Langer M., Herbort M.

Forschungsartikel (Zeitschrift) | Peer reviewed

Zusammenfassung

Introduction: Porcine flexor tendons, bovine extensor tendons, and human (semitendinosus) tendons are frequently used as substitutes for human ACL grafts in biomechanical in vitro studies. This study compares the biomechanical properties and structural differences of these tendons. Materials and methods: In this biomechanical study, fresh-frozen porcine flexor tendons, bovine extensor tendons, and human semitendinosus tendons were used (n = 36). The tendons were mounted in a uniaxial testing machine (Zwick/Roell) with cryo-clamps, leaving a 60 mm tendon part free between the two clamps. Specimens have been loaded to failure to evaluate the biomechanical parameters stiffness, yield load, and maximum load. A Total Collagen Assay Kit was used to detect differences in the total collagen type I concentration (n = 30). A one-way ANOVA was performed to detect differences in the means. The significance level was set at p < 0.05. Results: There were no significant differences in the stiffness between the groups (bovine 194 ± 43 N/mm, porcine 211 ± 63 N/mm, and human cadaveric 208 ± 58 N/mm). The yield and maximum loads were high (>1000 N) in all groups, but they were significantly increased in both animal specimens (means of 1681–1795 N) compared with human cadaveric specimen (means of 1289–1406 N; p < 0.01). No difference in the collagen type I concentration was detected (N.S.). Conclusion: Porcine flexor and bovine extensor tendons are eligible substitutes with similar stiffness and high failure loads compared with human cadaveric semitendinosus tendons in in vitro studies.

Details zur Publikation

FachzeitschriftArchives of Orthopaedic and Trauma Surgery (Arch Orthop Trauma Surg)
Jahrgang / Bandnr. / Volume136
Ausgabe / Heftnr. / Issue10
Seitenbereich1465-1471
StatusVeröffentlicht
Veröffentlichungsjahr2016
Sprache, in der die Publikation verfasst istEnglisch
StichwörterAnterior cruciate ligament reconstruction; Biomechanics; Bovine extensor tendon; In vitro; Porcine flexor tendon; Tendon properties

Autor*innen der Universität Münster

Domnick, Christoph
Kronenberg, Daniel
Langer, Martin
Raschke, Michael Johannes
Wieskötter, Britta

Preisverleihungen erhalten für die Publikation

Sporlastic Best Poster Award 2016, 2. Platz
Verliehen von: 33. Kongress der Gesellschaft für Arthroskopie und Gelenkchirurgie (AGA)
Verliehen an: Domnick C., Wieskoetter Britta, Schulze M., Kronenberg D., Wefelmeier M., Langer M., Raschke M., Herbort M.
Verleihung erfolgte am: 15.09.2016
Art der Preisverleihung: Preis für beste Veröffentlichung