Ion Yields in UV-MALDI Mass Spectrometry As a Function of Excitation Laser Wavelength and Optical and Physico-Chemical Properties of Classical and Halogen-Substituted MALDI Matrixes.

Soltwisch J, Jaskolla TW, Hillenkamp F, Karas M, Dreisewerd K

Forschungsartikel (Zeitschrift) | Peer reviewed

Zusammenfassung

The laser wavelength constitutes a key parameter in ultraviolet-matrix-assisted laser desorption ionization-mass spectrometry (UV-MALDI-MS). Optimal analytical results are only achieved at laser wavelengths that correspond to a high optical absorption of the matrix. In the presented work, the wavelength dependence and the contribution of matrix proton affinity to the MALDI process were investigated. A tunable dye laser was used to examine the wavelength range between 280 and 355 nm. The peptide and matrix ion signals recorded as a function of these irradiation parameters are displayed in the form of heat maps, a data representation that furnishes multidimensional data interpretation. Matrixes with a range of proton affinities from 809 to 866 kJ/mol were investigated. Among those selected are the standard matrixes 2,5-dihydroxybenzoic acid (DHB) and α-cyano-4-hydroxycinnamic acid (HCCA) as well as five halogen-substituted cinnamic acid derivatives, including the recently introduced 4-chloro-α-cyanocinnamic acid (ClCCA) and α-cyano-2,4-difluorocinnamic acid (DiFCCA) matrixes. With the exception of DHB, the highest analyte ion signals were obtained toward the red side of the peak optical absorption in the solid state. A stronger decline of the molecular analyte ion signals generated from the matrixes was consistently observed at the low wavelength side of the peak absorption. This effect is mainly the result of increased fragmentation of both analyte and matrix ions. Optimal use of multiply halogenated matrixes requires adjustment of the excitation wavelength to values below that of the standard MALDI lasers emitting at 355 (Nd:YAG) or 337 nm (N(2) laser). The combined data provide new insights into the UV-MALDI desorption/ionization processes and indicate ways to improve the analytical sensitivity.

Details zur Publikation

FachzeitschriftAnalytical Chemistry (Anal Chem)
Jahrgang / Bandnr. / Volume84
Ausgabe / Heftnr. / Issue15
Seitenbereich6567-76
StatusVeröffentlicht
Veröffentlichungsjahr2012 (07.08.2012)
Sprache, in der die Publikation verfasst istEnglisch
DOI10.1021/ac3008434
StichwörterPeptides; Ions; Cinnamates; Halogens; Spectrometry Mass Matrix-Assisted Laser Desorption-Ionization; Coumaric Acids; Lasers; Peptides; Ions; Cinnamates; Halogens; Spectrometry Mass Matrix-Assisted Laser Desorption-Ionization; Coumaric Acids; Lasers

Autor*innen der Universität Münster

Dreisewerd, Klaus
Institut für Medizinische Physik und Biophysik
Hillenkamp, Franz
Institut für Medizinische Physik und Biophysik
Jaskolla, Thorsten
Institut für Medizinische Physik und Biophysik
Soltwisch, Jens
Institut für Hygiene