Global left-ventricular function assessment using dual-source multidetector CT: effect of improved temporal resolution on ventricular volume measurement.

Puesken M, Fischbach R, Wenker M, Seifarth H, Maintz D, Heindel W, Juergens KU

Forschungsartikel (Zeitschrift)

Zusammenfassung

The purpose was to compare global left-ventricular (LV) function parameters measured with cine MRI with results from multiphase dual-source CT (DSCT) using 10 and 20 reconstruction phases. Twenty-eight patients with suspected or known CAD underwent DSCT coronary angiography. LV end-diastolic (EDV), end-systolic (ESV) and stroke volumes (SV), and ejection fraction (EF) were determined using LV segmentation and selection of specific phases from DSCT image sets reconstructed either at 5% or 10% steps through the R-R interval. Cine MRI served as the reference investigation. Threshold-based 3D-segmentation was feasible in all DSCT data sets. EDV and ESV were underestimated by DSCT, but showed excellent correlation (Pearson's correlation coefficient 0.95/0.97) to values obtained with MRI. Using data from 5% DSCT image reconstructions instead of 10% phase reconstructions, the position of the ED and ES phase was changed in 16 of 28 patients; ESVs were to found to be slightly smaller, whereas EDV were slightly larger, resulting in a systematic overestimation of LV EF by 1.9% (p=0.56). Threshold-based 3D segmentation enables accurate and reliable DSCT determination of global LV function with excellent correlation to cine MRI. Minor differences in LV EF indicate that both modalities are virtually interchangeable, even if the number of reconstructed phases is limited to 10% phase reconstructions.

Details zur Publikation

FachzeitschriftEuropean Radiology
Jahrgang / Bandnr. / Volume18
Ausgabe / Heftnr. / Issue10
Seitenbereich2087-2094
StatusVeröffentlicht
Veröffentlichungsjahr2008
Sprache, in der die Publikation verfasst istEnglisch
DOI10.1007/s00330-008-0982-1
StichwörterHumans; Reproducibility of Results; Coronary Angiography; Image Enhancement; Male; Sensitivity and Specificity; Aged; Ventricular Dysfunction Left; Imaging Three-Dimensional; Adult; Coronary Artery Disease; Tomography X-Ray Computed; Middle Aged; Female; Humans; Reproducibility of Results; Coronary Angiography; Image Enhancement; Male; Sensitivity and Specificity; Aged; Ventricular Dysfunction Left; Imaging Three-Dimensional; Adult; Coronary Artery Disease; Tomography X-Ray Computed; Middle Aged; Female

Autor*innen der Universität Münster

Maintz, David
Klinik für Radiologie Bereich Lehre & Forschung
Püsken, Michael
Klinik für Radiologie Bereich Lehre & Forschung
Seifarth, Harald
Klinik für Radiologie Bereich Lehre & Forschung
Wenker, Mirja
Klinik für Radiologie Bereich Lehre & Forschung